1. 請問 PC 要如何透過 USB 來控制 G5100A?
只須到 NI 的網站 www.ni.com - NI-VISA 下載驅動程式後,開機接上 USB,PC 成功辨識 G5100A,就可以透過本公司的應用軟體 Wavepat 或是自己編寫程式,來控制 G5100A 了。
2. 請問要如何用 G5100A 產生只有直流的電壓位準?
PICOTEST G5100A can output DC voltage in the range of -5 V DC to +5 V DC (into a 50-ohm termination).
To output a DC voltage from a G5100A:
-
Press [Utility] and choose “DC ON”.
-
Press soft-key [Vos] to activate the DC mode with the offset voltage as the output level. (0V default)
-
Using the knob or numeric keypad to modulate the level you desired.
-
press normal function keys to return to normal waveform operation.
3. 如何才能將 G5100A 的警告音及操作音關閉?
在 G5100A 的韌體版本1.6(含)前只有關閉系統警告音,而不能關閉操作時的聲音。只有韌體版本1.7以上才可以分別關閉系統警告音及操作音。以下是音效開/關步驟。
-
Press [Utility] and choose “System”.
-
Press soft-key [Sound] to on/off the sound of operation keys or press [Beep] to on/ off the warning beep.
-
Press [DONE] back to normal operation.
4. 何處可以取得 G5100A 的應用程式及使用手冊等資料?
所有的資料您都可以從附在儀器中的光碟片中取得,或者您可以到 PICOTEST 網站的技術支持頁面下載儀鼎儀器所有最新版的應用軟體程式、韌體更新程式或使用手冊等資料。
5. 如何使用 Pattern Output 功能?
G5100A waveform generator provides the capability of outputting a specified pattern of up to 256k points in 16-bit resolution. Similar to arbitrary waveforms, pattern output provides five built-in patterns and up to four user-defined patterns that are stored in non-volatile memory. The built-in patterns are exponential-rise, exponential-fall, negative-ramp, sinc, and cardiac. The default pattern output is an exponential-rise wave.
You may use the Wavepatt®, waveform and pattern editor to create the patterns you want or import the waveforms from the oscilloscope that you captured previously and follow below steps to set up pattern output.
-
Press the Utility button to enter the utility menu.
-
Press the softkey under [PATT MODE] to enter the PATTERN menu.
-
Press the softkey under [Fclk/Perd] to toggle between [Fclk] (frequency) and [Perd] (period).
-
Press the softkey under [Start Addr]/ [End Addr] for setting the start /end point of the pattern to output. Use the knob with the cursor keys to change the value. Or use the numeric keypad to enter a new value and then press [Enter] to finish the entry or the press [Cancel] to withdraw the changes.
-
Press the [Select wform] to enter selection menu:
-
Press [Built In] and choose the desired pattern from the five built-ins by pressing the corresponding softkey.
-
Press [Saved Wform] and choose the desired user-defined pattern by pressing the corresponding softkey.
-
One may delete a user-defined pattern by pressing the softkey under Delete Store and choose the pattern to delete by pressing the corresponding softkey
-
-
Press the [Output Setting] and then press [RPT.] to toggle between ON and OFF to enable/disable repeating output of the pattern.
-
To configure the trigger setting, press [Trig Setup] to enter the trigger setup menu:
-
To specify the trigger source, press the softkey under Src and then select among Ext (external) and Man (manual).
-
If manual trigger is selected, you may configure the trigger out signal by pressing the softkey under Trig Out and then select among OFF, rising-edge trigger and falling-edge trigger.
-
If external source is selected, you may press the softkey under Slope to toggle between rising edge trigger and falling edge trigger.
-
Press the softkey under DONE to finish the trigger setting.
-
-
After completed above setting. Press function key [Output] to generate the pattern out. The pattern would be outputted once only if the setting of [RPT.] is OFF in the [Output Setting].